Automatic Clean Ionizing Air Blower KF-19AY
TECHNICAL PARAMETERS
Category | Parameter | Category | Parameter |
Model | KF-19AY | Air volume | 2.56-4.07m³/min |
Input voltage | DC24V±5% | Ozone concentration | 0.004ppm (distance 50mm) |
lon balance | Automatic ion balance system 0±10V | Working temperature | 0-40℃ |
Working voltage | High frequency AC ±2200V | Working humidity | 15- 75%RH (No condensation or water droplets) |
Product Weight | 736g | Product Size | 187* 181 * 75.5 mm ( bracket exclusive) |
TEST CONDITIONS
Working voltage: AC110V/60HZ or AC220V/50HZ. Testing voltage: ±1000V – ±100V. Temperature: 23℃±2℃
Distance | Decay time (+/-) | Ion balance(+/-) | Remark |
300mm | 1.0s/-1.2s | 0±10V | 1.Testing method: Using charged plate monitor to test.
2.Decay time tested with the maximum air volume and voltage from ±1000V to ±100V. 3.Test in the central area of the front air window. |
600mm | 2.3s/-2.8s | 0±15V | |
900mm | 4.0s/-4.4s | 0±20V |
Automatic Clean Ionizing Air Blower KF-19AY